• Underground parking garage - Taktik-Trainer - Rauchhaus
  • Smoke barrier and smoke curtain inside the underground parking garage
  • Underground parking garage from Taktik-Trainer
  • Taktik-Trainer Underground parking garage interior view
  • Taktik-Trainer Underground parking garage
  • Large underground parking garage Taktik-Trainer
  • Large underground parking garage with white floor tiles
  • Underground parking garage, small brown floor tiles

Underground parking garage

Starting at 2.079,99 €

Payment optionsinfo
Our payment methods: Advance payment, invoice and installment payment.
In the online shop Advance payment activated by default. From the second order with a customer account payment by invoice is possible. An installment payment is offered to companies, authorities and organizations upon request (not for private customers).

For a non-binding Offer, Please add the relevant items to your shopping cart. You can then generate an automatically generated quote.

For organizations, we are happy to accommodate individual payment procedures.
Contact:
Phone: +49 (0)7171 – 99 810 31
E-mail: info@bos-akademie.de
For more information, see: Shipping and payment conditions

The underground parking garage module enables training in fire suppression and smoke ventilation in confined, smoke-filled environments with challenging access routes.

Delivery time: 20-30 business days

SKU: N/A Categories: , ,

Description

The Underground Parking Garage Starter Package is a complete Taktik-Trainer system designed to realistically simulate an underground parking structure. Featuring parking spaces, narrow access routes, stairwells, and multiple smoke compartments, it recreates the typical challenges of underground parking garage fires in a highly realistic training environment—ready to use without the need for additional modules. For even more training possibilities, the starter package can optionally be combined with the Multi-family home , allowing scenarios such as smoke-filled stairwells or rescues from an adjacent building to be practiced as well.

Why Underground Parking Garages Present Unique Challenges

Underground parking garage fires are among the most challenging incidents firefighters face. Limited visibility caused by smoke, confined access routes, and difficult communication below ground make coordinated operations particularly demanding. The Underground Parking Garage Module for the Taktik-Trainer allows these conditions to be practiced in a realistic training environment—without real-world risks, but with maximum training value.

Typical Trainings Scenarios

  • Vehicle Fire: Tactical response to a passenger vehicle fire involving smoke development and limited visibility in confined parking areas.
  • Smoke-Filled Stairwell: Training orientation, communication, and tactical decision-making when escape routes and access points are obstructed by smoke.
  • Rescue Operations: Search and rescue of occupants under challenging conditions, including the use of a smoke and heat exhaust system (RWA).

Smoke Control and Ventilation

The module is equipped with two smoke and heat exhaust (RWA) units. Combined with the included positive pressure ventilation fans, a variety of smoke control and ventilation strategies can be practiced and evaluated directly—making it an ideal training environment, especially when used together with the Miniature LUF.

Features

  • Realistic representation of an underground parking garage with parking spaces and confined access routes
  • Training for incidents involving limited visibility and smoke conditions
  • Smoke and Heat Exhaust System (RWA) for smoke extraction and ventilation
  • Authentic conditions for analyzing fire progression and smoke behavior
  • Training environment for coordination and communication during firefighting operations

Included Components:

Large Version with 12 Base Plates:

  • 12 Base Plates
  • Support Columns
    • Three-Sided Columns
    • One-Sided Columns
    • Two-Sided Columns
    • Corner Columns
  • Wall Elements, including:
    • Interior doors
    • single transparent walls
    • single frosted walls
    • double transparent walls
    • double frosted walls
  • Intermediate floor elements (including glass inserts), including:
    • floors 1x1
    • floors 1x1 with top edge
    • floors 1x1 with right edge
    • corner floors
    • floors 1x2
    • floors 1x2 with top edge
  • 2 separate stair rooms
  • 2 staircases
  • 2 smoke and heat exhaust system (SHE) for parking garage + cover
  • 4 elevator
  • 1 Entrance with Grille Gate
  • Landscaping & Playground
  • 3 figurine sets
  • 6 cars
  • Emergency Exit Door
  • 2 Smoke Generators
  • 2 Positive Pressure Ventilation Fans
  • 2 Heat Source Units
  • 1 Smoke Curtain
  • 1 Fire Barrier

Small Version with 6 Base Plates:

  • 6 floor plates
  • Support Columns
    • Three-Sided Columns
    • One-Sided Columns
    • Two-Sided Columns
    • 6 corner pillars
  • Wall Elements, including:
    • Interior doors
    • single transparent walls
    • single frosted walls
    • double transparent walls
    • double frosted walls
  • Intermediate floor elements (including glass inserts), including:
    • floors 1x1
    • floors 1x1 with top edge
    • floors 1x1 with right edge
    • corner floors
    • floors 1x2
    • floors 1x2 with top edge
  • 1 stair room
  • 1 staircase
  • 1 RWA underground parking garage
  • 2 elevator
  • 1 Entrance with Grille Gate
  • Landscaping & Playground
  • 2 figurine sets
  • 4 cars
  • Emergency Exit Door
  • 2 Smoke Generators
  • 2 Positive Pressure Ventilation Fans
  • 2 Heat Source Units

Additional information

Weight N/A
Dimensions N/A
Variant

6 floor tiles (brown), 6 floor tiles (white), 12 floor tiles (brown), 12 floor tiles (white)

You may also like…

  • ExtensionsTaktik-Trainer

    LUF – Firefighting Support Vehicle

    Compact miniature LUF for realistically simulating smoke ventilation in large areas of the Taktik-Trainer. Ideal for underground parking garages and industrial halls.

    incl. VAT

    plus shipping costs - Price applies to deliveries to Germany, Austria and Switzerland.

  • Starter packagesTaktik-Trainer

    Multi-family house

    The starter packet "Multi-family home" enables realistic fire simulations for training and education. With additional residential units, smoke and heat technology as well as movable doors and windows, it offers even more options for tactical exercises and fire safety education.

    incl. VAT

    plus shipping costs - Price applies to deliveries to Germany, Austria and Switzerland.

    Delivery time: 20-30 business days