Taktik-Trainer, the modular training system

For Simulating Realistic Emergency Response Scenarios

Taktik Trainer Residential Building Configurator

With the Taktik-Trainer, you can visualize in training what is difficult to explain in the classroom. You can role-play operational situations on a model, change individual factors, and see immediately how this affects the subsequent course of events. From reconnaissance and the selection of resources to the tactical approach at the scene.

An important aspect is the spread of smoke and heat. The model demonstrates how smoke layers build up, what airflow paths develop, and what effect ventilation measures have on the building. Furthermore, it allows for training in rescuing people, alternative attack routes, selecting equipment, vehicle positioning, command and control, and communication. Because the entire group can observe what is happening inside the building, every decision can then be evaluated together.

Designed by emergency responders for emergency responders. Developed from practical experience. Made in Germany.

What makes the Taktik-Trainer stand out

Modular and expandable

The Taktik-Trainer can be modified, reconfigured, and expanded at any time. From single-family homes to multi-family dwellings with basements, garages, and attics, all the way to underground parking garages and other special structures. This allows you to cover a wide range of scenarios with just one system.

Thermodynamically realistic smoke

The smoke generator and heat source always work together. Only through their interaction does the smoke rise, layer, and reveal airflow paths. This allows us to understand why smoke and heat develop in the way they do in a given location.

Based on real-world experience, made in Germany

The system is backed by experienced emergency responders, instructors, and engineers. Feedback from training and operational service is continuously incorporated into new components and functions. Development and manufacturing take place in Germany.

The modular system

The Taktik-Trainer is not a finished model, but a modular system. Base plates, wall elements, doors, windows, floors, and extensions combine to create a building that fits your training concept. The structure can remain as is, individual areas can be modified for a new scenario, and further components can be added later without having to replace what's already there.

Taktik-Trainer: Modular construction | Smoke house
Taktik-Trainer: Top view of the ground floor
  • Removable projectiles: Each floor can be completely removed. This allows you to access the rooms below without any structural alterations.
  • Service hatch: You can make adjustments to the model via the service hatch while the exercise is running.
  • Mobile smoke generators: A generator fills the room it's in with smoke, and through open doors, also the adjacent rooms. Several generators can be used simultaneously in different rooms. Doors, windows, airflow, and ventilation determine how far the smoke spreads.
  • Selectable transparency: Walls, floors, and ceilings can be designed to be transparent or opaque. This allows you to determine, even during the construction phase, which areas of the building are visible to the group and which are not.
  • Removable privacy screens: The visual barriers are wedged between two pillars from the outside, thus blocking the view through the transparent walls. Several placed side by side can cover larger areas. Individual barriers can be removed during the exercise using a small handle. This allows the group to work their way into the building step by step, instead of seeing everything from the start.
  • Movable doors, windows and smoke barrier: Doors can be opened and closed, windows can be closed, tilted, or completely removed, and a mobile smoke barrier can be installed and removed. This is operated from the outside via a rod that is inserted through the hole in the wall element. A wall element with a hole must be installed at the respective location.

This is how an exercise proceeds

1

Establish a position
Place the smoke generator in the room where the scenario begins. Use multiple generators for multiple fire rooms.

2

Generating thermals
The heat source warms the air, the smoke rises and layers. Both components are needed together.

3

Observing together
The whole group can see how the situation develops and where the smoke spreads by looking at the transparent walls, floors and ceilings.

4

Act tactically
Choose the attack route, assign the necessary resources, open or close doors and windows, deploy the smoke curtain, position the aerial ladder, or ventilate the area. Afterwards, everyone can see the effect of the decision.

This is how the Taktik-Trainer is constructed.

The foundation consists of the base plates. A single base plate measures 36 by 36 centimeters; the starter kit contains four plates, together providing a footprint of 72 by 72 centimeters. You attach the pillars to the base plates, and then insert the wall elements between them. At this point, you decide where a solid wall will be and where a door or window will be placed. Intermediate floors, optionally transparent or opaque, complete each story, and stairs connect the floors. Because all components are based on the same grid system, the floor plan can be modified later.

Aerial Ladder Trainer with the Taktik-Trainer

Building components

  • Floor slabs and pillars: Each base plate measures 36 × 36 cm; four of them make up the base area of the starter kit. The pillars are then placed on top of the plates.
  • Wall elements Transparent or closed, with holes for operating doors and smoke barrier from the outside.
  • Movable doors and windows: Interior and exterior doors that can be opened and closed, as well as various types of windows that can be closed, tilted or completely removed.
  • Mezzanines and stairs: Intermediate floors can be either transparent or closed; stairs connect the individual floors.
  • Mobile smoke barrier: It can be placed and removed from the outside using a pole, just like the doors, even in the middle of an exercise.
  • View blocker: They obstruct the view through transparent walls and can be removed individually. They are included in the starter kits.

Technical components

  • Smoke generator: It produces dense white smoke. Attachments for the stove and washing machine, as well as a flickering flame LED, realistically depict the source of the fire.
  • Heat source device: The thermals provide the energy that causes the smoke to rise and layer. It is powered by a tea light.
  • High-pressure fan: It generates a directed airflow for supply and exhaust ventilation as well as tactical ventilation.
  • Wind generator: simulates natural wind conditions and shows how wind affects smoke propagation and ventilation.
  • LUF, Firefighting Support Vehicle: Scale model for smoke extraction from large areas, such as underground parking garages.

Extensions

Each extension can be retrofitted individually and combined with the existing components.

  • Tiered set: adds another floor for multi-story buildings and longer attack routes.
  • Basement: It also includes a basement structure for basement fire protection and access points below ground level.
  • Gable roof: It enables roof scenarios and fits various rectangular floor plans.
  • Garage: with movable garage door and vehicle.
  • Balcony and roof terrace railings: for the representation of balconies and terraces as rescue or attack points.
  • Equipment set: Scale models of firefighting equipment such as extension ladders, sliding ladders, distributors, standpipes, jet nozzles, hose baskets, and axes are available. These allow you to practice selecting equipment for the attack team. The version with a hose also allows you to practice hose handling at a building.
  • DLA(K) Aerial Ladder Trainer: Scale model aerial ladder for positioning, selecting suitable access points and rescue operations on different building levels.

What you will train with it

The Taktik-Trainer makes tactical relationships visible that are difficult to convey in the classroom. Typical training topics:

  • Operations in residential buildings, underground parking garages and special buildings
  • People Rescue and Operational Priorities
  • Alternative Attack Routes
  • Selection and allocation of resources
  • Ventilation, tactical ventilation and the influence of open or closed doors
  • Leadership and decision-making as well as communication in operations
  • Deployment of the aerial ladder, vehicle positioning and operational organization
  • Preventive fire protection as well as evacuation and clearing
  • Structured Post-Incident Debriefings
  • Basic training and breathing apparatus training
  • Fire prevention education and public relations

Technical data

Starter packagesSingle-family house, multi-family house, underground parking garage
ExtensionsFloor set, basement, pitched roof, garage, balcony and roof terrace railings, equipment set, DLA(K) Aerial Ladder Trainer
Base plate36 × 36 cm per panel; 4 pieces in the starter pack (2×2), resulting in a base area of 72 × 72 cm
Dimensions of underground parking garage108 × 72 × 38.6 cm (6 base plates, 3×2), large version 144 × 108 × 38.6 cm (12 base plates, 4×3)
Floor heightapproximately 20 cm per floor
Weight (approx.)Single-family house 20 kg, multi-family house 30 kg, underground garage 25 kg, large underground garage 50 kg
Electronic componentsSmoke generator, high-pressure fan, wind generator, LUF
Smoke generatorUSB-C battery (RCR123A Li-Ion 3.7 V 950 mAh USB-C, not included), remote control, flame LED
Power supply for fans and LUFHigh-pressure fan 3× AAA, wind generator 6× AAA, LUF 3× RCR123A Li-Ion 3.7 V (batteries and rechargeable batteries not included)
ProductionMade in Germany

The Taktik-Trainer is intended for professional and institutional users, not for private use. Use only the approved smoke fluid, and observe the operating instructions and safety data sheet. Avoid direct inhalation of the training smoke; ventilate after use.

Here's how to get your non-binding offer

You have two options. Configure your system yourself in the shop and have a non-binding offer sent directly to you by email, anytime and even outside of our business hours. Or contact us, and we will work with you to create the perfect configuration.

1

Select products
Add your starter package and the desired extensions to your shopping cart.

2

„Click "Create offer"
In the shopping cart, click the button and enter your details.

3

Receive a non-binding offer
You will receive the offer by email. Take your time to review it, ask questions, or have it adjusted – whatever suits you best.

Popular products

  • Starter packagesTaktik-Trainer

    Residential Building Configurator

    The “Residential Building” module is a customizable training structure for realistic emergency response training. Configurable floors, roof, basement, and garage sections make it possible to create a wide range of scenarios – from a single-family residence to a complex multi-unit building.

    incl. VAT

    plus shipping costs - Price applies to deliveries to Germany, Austria and Switzerland.

    Delivery time: 20-30 business days

  • ExtensionsStarter packages

    Underground parking garage

    The underground parking garage module enables training in fire suppression and smoke ventilation in confined, smoke-filled environments with challenging access routes.

    incl. VAT

    plus shipping costs - Price applies to deliveries to Germany, Austria and Switzerland.

    Delivery time: 20-30 business days

  • Sale!
    Drehleiter-TrainerExtensions

    DLA(K) Aerial Ladder Trainer

    The scale-model aerial ladder adds realistic training scenarios to your Taktik-Trainer, including rescue operations, planning apparatus positioning, and exterior firefighting from the aerial platform.

    incl. VAT

    plus shipping costs - Price applies to deliveries to Germany, Austria and Switzerland.

Get in touch

Questions about configuration, delivery times, or suitable training? Write to us, we will get back to you promptly.

name
e.g. fireman/woman, instructor, commander, ...

Bollin Consulting GmbH, BOS-Akademie
Sebaldstraße 23, 73525 Schwäbisch Gmünd
info@bos-akademie.de · +49 7171 99 810 31

en_US
✉️ Newsletter